Basic Info.
Application
Construction, Power Station
Voltage
Low and Medium Voltage Cable
Wire Core Material
Red Copper Wire
Certification
ISO, CE, UL
Transport Package
Sea Worthy Packing
Specification
National Standard
Origin
Yanggu, Shandong, China
Product Description
0.6/1KV or Below PVC Insulated and Sheathed Power Cable
This product is used for the Power Transmission of Electrical Circuit of rated AC Voltage 0.6/1KV.
Production Standard:
China Standard: GB/T12706.1
IEC Standard: IEC60502.
Feature:
Cable Conductor Long time working Temperature should be less than 70ºCDuring Short Circuit (Max Time should be less than 5 Seconds), Max Temperature of Cable Conductor is less than 160ºCSurrounding Environmental Temperature during Cable Laying should not be less than 0ºC.
Basic Model
Model | Name | Application |
Copper | Al |
VV | VLV | PVC Insulated PVC sheathed Power Cable | It is used inside Room, Tunnel, Cable Groove or Pipes. Cable cannot be hit by External Mechanical Force. |
VV22 | VLV22 | PVC Insulated PVC sheathed Steel Strip Armored Power Cable | This is laid underground, it Can bear some External Mechanical Force, But it cannot bear large Pulls. |
Note:
"Flame Retardant" "Fire Resistant" Cable can also be offer, For "Flame Retardant" Type, "ZR-" should be added before the previous model code, For "Fire Resistant" Cable, "ZH-" Should be added. VV32 Type and VLV32 Type Steel Wire Armored Power Cable can also be offered. Single Core Steel Wire Armored Power should be Magnetically isolated
Products Scope:
Model | Core | Cross Section MM2 |
Copper | Al |
VV VV22 | VLV VLV22 | 1 | 1.5~500 2.5~500 10~500 |
VV VV22 | VLV VLV22 | 2 | 1.5~185 2.5~185 4~185 |
VV VV22 | VLV VLV22 | 3 | 1.5~300 2.5~300 4~300 |
VV VV22 | VLV VLV22 | 4 | 2.5~300 2.5~300 4~300 |
VV VV22 | VLV VLV22 | 3+1 | 4~300 4~300 |
Note:
5 Cores Cable can also be offeredArmor Layer of Single Core Armored Cable for AC System should be wrapped with Non-Magnetic Metal Strips.
Technical Parameters:
1): Max DC Resistance of the Conductor in 20ºC should meet Requirement of 2nd Type Conductor in the Standard of GB/T3956
2): A.C. Voltage Test: Single Core Non-Shielding Core should be immersed into water for 1 hour and impose Testing Voltage of 3.5KV/5 Min between the Conductor and Water. For Multi-Core Cable, Please input Testing Voltage of 3.5KV/5 Min between each core and all the rest cores, after testing, Insulation layer should be Breakdown Free.
Approximate O.D and Weight of the Cable
Core× Nominal Cross Section mm2 | Approximate O.D mm | Approximate Weight kg/km | Approximate O.D mm | Approximate Weight kg/km |
VV | VLV | VV22* | VLV22* |
1×1.5 | 5.8 | 50 | / | / | / | / |
1×2.5 | 6.2 | 62 | 47 | / | / | / |
1×4 | 7.1 | 87 | 63 | / | / | / |
1×6 | 7.6 | 110 | 75 | / | / | / |
1×10 | 8.9 | 166 | 96 | 12.4 | 346 | 270 |
1×16 | 9.9 | 234 | 133 | 13.4 | 432 | 331 |
1×25 | 11.7 | 345 | 186 | 15.2 | 574 | 414 |
1×35 | 12.6 | 450 | 229 | 16.2 | 692 | 475 |
1×50 | 14.6 | 585 | 276 | 18.1 | 863 | 553 |
1×70 | 16.3 | 800 | 366 | 19.8 | 1133 | 700 |
1×95 | 18.5 | 1065 | 475 | 22.0 | 1432 | 844 |
1×120 | 20.2 | 1328 | 586 | 23.7 | 1705 | 962 |
1×150 | 22.5 | 1600 | 702 | 26.0 | 2044 | 1120 |
1×185 | 24.8 | 1990 | 850 | 28.3 | 2438 | 1296 |
1×240 | 27.8 | 2546 | 1060 | 31.5 | 3057 | 1570 |
1×300 | 30.7 | 3140 | 1292 | 34.2 | 3926 | 2070 |
1×400 | 34.7 | 4127 | 1651 | 38.0 | 5084 | 2608 |
1×500 | 39.0 | 5259 | 2016 | 43.0 | 6295 | 2936 |
2×1.5 | 10.4 | 118 | / | / | / | / |
2×2.5 | 11.3 | 151 | 118 | / | / | / |
2×4 | 13.0 | 210 | 159 | 16.0 | 424 | 374 |
2×6 | 13.9 | 263 | 192 | 17.1 | 494 | 425 |
2×10 | 16.5 | 394 | 242 | 19.8 | 665 | 497 |
2×16 | 18.6 | 541 | 334 | 21.8 | 845 | 638 |
2×25 | 22.0 | 794 | 468 | 25.3 | 1154 | 827 |
2×35 | 24.2 | 1037 | 585 | 27.5 | 1436 | 982 |
2×50 | 20.3 | 1236 | 592 | 23.6 | 1580 | 940 |
2×70 | 22.7 | 1647 | 745 | 26.0 | 2210 | 1302 |
2×95 | 26.2 | 2189 | 966 | 29.1 | 2800 | 1530 |
2×120 | 28.8 | 2640 | 1144 | 32.6 | 3400 | 1850 |
2×150 | 32.2 | 3280 | 1410 | 36.2 | 4150 | 2198 |
2×185 | 35.8 | 4006 | 1703 | 39.5 | 5025 | 2592 |
3×1.5 | 10.6 | 142 | / | / | / | / |
3×2.5 | 11.7 | 187 | 139 | / | / | / |
3×4 | 13.6 | 264 | 189 | 16.6 | 489 | 413 |
3×6 | 14.7 | 335 | 226 | 17.7 | 578 | 472 |
3×10 | 17.4 | 514 | 290 | 20.4 | 801 | 560 |
3×16 | 19.7 | 729 | 418 | 22.7 | 1058 | 743 |
3×25 | 23.4 | 1085 | 596 | 26.4 | 1470 | 979 |
3×35 | 25.8 | 1430 | 748 | 28.8 | 2148 | 1370 |
3×50 | 25.5 | 1820 | 839 | 28.5 | 2457 | 1489 |
3×70 | 28.4 | 2400 | 1080 | 31.7 | 3122 | 1768 |
3×95 | 32.8 | 3155 | 1418 | 36.7 | 4055 | 2218 |
3×120 | 35.7 | 3982 | 1747 | 39.6 | 4925 | 2606 |
3×150 | 40.0 | 4950 | 2135 | 44.0 | 6050 | 3154 |
3×185 | 44.4 | 6156 | 2610 | 48.6 | 7299 | 3721 |
3×240 | 49.7 | 7886 | 3308 | 53.9 | 9223 | 4584 |
3×300 | 54.3 | 9647 | 4059 | 58.7 | 11022 | 5423 |
4×2.5 | 12.2 | 225 | 166 | / | / | / |
4×4 | 15.0 | 332 | 231 | 18.0 | 581 | 480 |
4×6 | 16.2 | 430 | 270 | 19.2 | 703 | 551 |
4×10 | 19.7 | 641 | 393 | 22.7 | 891 | 637 |
4×16 | 22.0 | 902 | 499 | 25.0 | 1175 | 771 |
4×25 | 26.0 | 1438 | 766 | 29.0 | 1998 | 1347 |
4×35 | 28.7 | 1815 | 919 | 31.7 | 2585 | 1660 |
4×50 | 30.4 | 2380 | 1091 | 33.4 | 3100 | 1819 |
4×70 | 33.8 | 3202 | 1398 | 37.0 | 4039 | 2228 |
4×95 | 38.2 | 4300 | 1860 | 41.5 | 5200 | 2800 |
4×120 | 42.0 | 5269 | 2186 | 45.5 | 6400 | 3320 |
4×150 | 46.4 | 6554 | 2748 | 49.9 | 7806 | 3958 |
4×185 | 51.2 | 8090 | 3325 | 54.9 | 9442 | 4700 |
4×240 | 55.3 | 10355 | 4056 | 59.0 | 11887 | 5734 |
4×300 | 64.5 | 12776 | 4950 | 68.2 | 14356 | 6995 |
3×4+1×2.5 | 14.5 | 310 | 215 | 17.5 | 543 | 447 |
3×6+1×4 | 16.1 | 403 | 268 | 19.1 | 661 | 526 |
3×10+1×6 | 18.9 | 600 | 363 | 21.9 | 894 | 625 |
3×16+1×10 | 21.6 | 858 | 505 | 24.6 | 1195 | 807 |
3×25+1×16 | 25.0 | 1315 | 693 | 28.0 | 1679 | 1082 |
3×35+1×16 | 27.6 | 1645 | 834 | 30.6 | 2243 | 1458 |
3×50+1×25 | 29.6 | 2124 | 996 | 32.6 | 2867 | 1736 |
3×70+1×50 | 33.2 | 2867 | 1285 | 36.2 | 3698 | 2099 |
3×95+1×50 | 38.0 | 3824 | 1664 | 42.1 | 4796 | 2636 |
3×120+1×70 | 41.5 | 4784 | 2060 | 45.5 | 5900 | 3129 |
3×150+1×70 | 44.6 | 5790 | 2473 | 48.4 | 6921 | 3623 |
3×185+1×95 | 49.7 | 7164 | 3050 | 54.2 | 8437 | 4369 |
3×240+1×120 | 55.9 | 9414 | 3842 | 60.3 | 11163 | 5586 |
3×300+1×150 | 61.6 | 11749 | 4920 | 66.0 | 13465 | 6445 |
Armor Layer of Single Core Armored Cable for AC System should be wrapped with Non-Magnetic Metal Strips.
Single Core Steel Wire Armored Power should be magnetically isolated
7. Cable Capacity:(0.6/1kV)
Cabling in Open Air:
Center Distance when Single Core Cables are paralleled laid: 185MM2 or Below: 2 Times of the Cable Diameter240MM2 or Above: 90MM.
2): Max Working Temperature of Conductor: 70ºC,Surrounding Temperature: 30ºC.
Correction Factor of Capacity under Different Air Temperature:
Air Temperature:ºC | 20 | 25 | 30 | 35 | 40 | 45 |
Correction Factor | 1.12 | 1.06 | 1.00 | 0.94 | 0.87 | 0.79 |
Address:
Xiangguang Qianyi (Ecology) Industrial Zone, Yanggu County, Liaocheng, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics
Company Introduction:
YangguXinhui cable co. Ltd. Is located in Yanggu County, 10 kilometers north of the auspicious light billions of (ecological) industrial park, according to Liaoyang highway, Beijing-kowloon railway, chat, close to the city of Liaocheng, transportation, communication, logistics is very convenient. Company was founded in 1997, is specialized in cable R&D and manufacturing of modern enterprise. After years of development, has been formed covers an area of nearly 160 mu, building area of 2.5 square meters, annual output value of 380 million yuan, has more than 200 sets of production, auxiliary equipment nearly all kinds of test instruments more than 40 sets of employees nearly 380 people, intermediate and senior technical personnel 110 people, quality inspection (measurement) check test personnel 10 people, can produce various specifications of wire and cable thousands of, and in the cable industry has a certain influence of the province of large wire and cable manufacturing enterprises.
The production of polyvinyl chloride insulated wire and cable our factory produced in 2002 won some national electrician certification commission and safety certification, flame retardant, fire-resistant wire and cable in June 2013 by fire type approval, power cable, control cable, in 2001 won the national industrial products production license, in December 2002 passed the ISO9001: 2000 quality management system certification. Rice.